KNX AC brand Solution

Find your gateway solution to integrate AC units into KNX systems. Our AC Interfaces makes easy the integration and ensures the compatibility as a major factor to enable maximum efficiency.
HMS_web-icon_Backup

Ensure energy savings

Intesis AC gateways allow to reduce considerably the energy consumption of buildings while contributing to environment protection.

HMS_web-icon_Solution Partner

Improve user's comfort

The goal is to reduce energy while improving user’s comfort. With Intesis these are not mutually exclusive outcomes!

fan-and-vane

Leading with leaders

We are the indisputable market leader in AC integration thanks to have the continuous support of the major AC manufacturers.

Mitsubishi Electric Domestic, Mr.Slim and City Multi to KNX Interface

The Mitsubishi Electric-KNX gateway allows fully bi-directional communication between Mitsubishi Electric Domestic, Mr.Slim and City Multi Air Conditioner units and KNX installations.

FEATURES

  • KNX certified.
  • Configured by ETS standard configuration tool.
  • Reduced dimensions allowing a quick installation inside the Air Conditioner unit.
  • Offered all the required DPT objects to be compatible with all KNX thermostats in the market.
  • Energy efficiency functions, such as “timeout”, “open window” or “Occupancy”. Costs related to HVAC systems in a building are one of the highest and these functions allow to reduce them.
  • Smooth integration of KNX thermostats allowing the control of the AC unit by the own temperature sensor of the thermostat.
  • Simultaneous control of the AC unit by the IR remote controller and by KNX.
  • Total control and monitoring of the AC unit from KNX, including AC unit’s internal variables, running hours counter (for filter maintenance control) and error indication.
  • Up to 5 scenes can be saved and executed from KNX.
mitsubishi-electric-domestic-slim-city-multi-knx-interface

Use Case

Integration of Mitsubishi Electric Domestic Air Conditioner Units into a KNX installation.

ME-AC-KNX-1-V2

Description

DIRECT CONNECTION TO INDOOR UNITS

The gateway is wired directly to an indoor unit. This allows not only the control of the main AC functions such as operating mode, fan speed, temperature setpoint…but the monitoring of errors, alarms and some internal variables.

EASY TO SET UP BY ETS (STANDARD KNX TOOL)    

The connection between the two networks is quickly set up in the ETS configuration tool using the product database available to download. Thanks to the high number of supported KNX DPTs and the KNX certification, the gateway ensures interoperability with any KNX device in the market.

Technical Documentation

User Manual General information about this product Download
Installation Manual Learn how to install the device in your project Download
HVAC Compatibility tool Find the appropriate solution for your HVAC integration Open
HVAC Compatibility Check your HVAC compatibility Download
EC Declaration of Conformity Check the product certification Download

Programming Tool

ETS Data Base Configuration tool Download

Commercial Documentation

Marketing Datasheet Discover all the integration solutions for Mitsubishi Electric
Download
Intesis Brochure
Know more about the Intesis current available products
Download

HVAC Compatibility

Ensure the compatibility of this gateway with your AC model by visiting https://compatibility.intesis.com/

Compatible AC models

MFZ-KA | MFZ-KJ | MLZ-KA | MLZ-KP-NA | MSY-A | MSY-GL | MSZ-A | MSZ-AP - VG-E1 | MSZ-AP - VG-EN1 | MSZ-AP - VGK-E1 | MSZ-AP - VGK-EN1 | MSZ-CGE | MSZ-DM | MSZ-EF | MSZ-FA | MSZ-FD | MSZ-FH | MSZ-GA | MSZ-GB | MSZ-GC | MSZ-GE | MSZ-GF | MSZ-GL | MSZ-HR | MSZ-HA | MSZ-HC | MSZ-HJ | MSZ-LN | MSZ-SF | MSZ-WN | PCA-M | PCA-RP | PCA-RP – HA | PCA-RP – HAQ | PEAD-A - AA5 | PEAD-RP | PEAD-SP | PEAD-SM - JA | PEAD-SM - JAL | PEAD-M - JA | PEAD-M - JAL | PEY-P - JA | PEAM125GAA | PLA-RP - | PLA-ZM - | PLA-ZRP - | PLA-SM - | PLA-M-EA-A | PLY-P-BA | PKA-M - | PKA-RP - | PSA-RP - | SEZ-KA - | SEZ-KC - | SEZ-KD - | SEZ-M - | SLZ-KA - | SLZ-KF - | SLZ-M - | PEA-RP - | PEH-RP - | PCFY-P - VKM-ER1 (since end 2013) | PEFY-P - NMAU-E3 | PEFY-P - NMHSU-E (since end 2013) | PEFY-P - VMA-E | PEFY-P - VMA-E2 | PEFY-P - VMA-ER3 (since end 2013) | PEFY-P - VMAL-E | PEFY-P - VMAL-E2 | PEFY-P - VMH(S)-E (since end 2013) | PEFY-P - VMR-E (since end 2013) | PEFY-P - VMS1-E (since end 2013) | PFFY-P - VKM-E2 (since end 2013) | PFFY-P - VLRMM-E (since end 2013) | PKFY-P - VBM-ER3 | PKFY-P - VHM-ER2 (since end 2013) | PKFY-P - VKM-ER1 (since end 2013) | PLFY-P - VBM-E (since end 2013) | PLFY-P - VBM-ER3 (since end 2013) | PLFY-P - VEM-E | PLFY-P - VCM-ER2 (since end 2013) | PLFY-P - VFM-E | PLFY-P - VFM-E1 | PLFY-P - VLDM-E (since end 2013) | PMFY-P - VBM-E#2 | PMFY-P - VBM-ER3 | PMFY-P - VBM-ER4 (since end 2013) | PLFY-WP - VFM-E | PLFY-WP - VFM-E1 | PLFY-WP - VBM-E | PEFY-WP - VMA-E | PEFY-WP - VMS1-E | PFFY-WP - VLRMM-E | MSY-D | MSY-GA | MSY-GE | MSZ-D | MSZ-FE | MS-A | PCA-A | PEA-A | PEAD-A | PKA-A | PLA-A | PVFY-P - E00 (since end 2012) | PCFY-P - NKMU-ER1.TH (since end 2012) | PEFY-P - NMSU-ER2.TH (since end 2012) | PEFY-P - NMAU-E | PEFY-P - NMAU-E2 (since end 2012) | PEFY-P - NMAU-E3 (since end of 2013) | PEFY-P - NMHSU-E (since end 2012) | PEFY-P - NMHU-E (since end 2012) | PEFY-P - NMHU-E2 (since end of 2013) | PFFY-P - NEMU-E (since end 2012) | PFFY-P - NRMU-E (since end 2012) | PKFY-P - NBMU-E2 (since end 2012) | PKFY-P - NHMU-E2 (since end 2012) | PKFY-P - NKMU-E2.TH (since end 2012) | PLFY-P - NBMU-ER2 (since end 2012) | PLFY-P - NCMU-ER4.TH (since end 2012) | PLFY-P - NFMU-E | PMFY-P - NBMU-ER5 (since end 2012) | PVFY-P - NAMU-E | MSXY-FD | SL - AKLR | PL - BAK | PK - FAKLD | PC - GAKD | PS - GAKD | SE - AKR | SE - AKLR | PE - EAK | PE - EAKT | PEH - EAK | PEH - EAKH | PED - AAK | PLFY-P - EMG6 | PK - GAKLD | PE - GAK | PE - GAKT | PKH - GAKL | PKH - FAK | PCH - GAK | PSH - GAK | PE(H) - EAK | MSC-GA - VB | PCFY-P100VKM-E | PCFY-P125VKM-E | PCFY-P40VKM-E | PCFY-P63VKM-E | PEFY-M100 VMA2-A | PEFY-M100 VMA-A | PEFY-M125 VMA2-A | PEFY-M125 VMA-A | PEFY-M140 VMA-A | PEFY-M20 VMA2-A | PEFY-M20 VMA-A | PEFY-M25 VMA2-A | PEFY-M25 VMA-A | PEFY-M32 VMA2-A | PEFY-M32 VMA-A | PEFY-M40 VMA2-A | PEFY-M40 VMA-A | PEFY-M50 VMA2-A | PEFY-M50 VMA-A | PEFY-M63 VMA2-A | PEFY-M63 VMA-A | PEFY-M71 VMA2-A | PEFY-M71 VMA-A | PEFY-M80 VMA2-A | PEFY-M80 VMA-A | PEFY-P100VMA3-E | PEFY-P100VMHS2-E P | PEFY-P100VMHS-E | PEFY-P125VMA3-E | PEFY-P125VMHS-E | PEFY-P125VMHS-E-F | PEFY-P140VMHS-E | PEFY-P15VMS1-E | PEFY-P200VMHS-E | PEFY-P200VMHS-E-F | PEFY-P20VMA3-E | PEFY-P20VMR-E-L | PEFY-P20VMS1-E | PEFY-P250VMHS-E | PEFY-P250VMHS-E-F | PEFY-P25VMA3-E | PEFY-P25VMR-E-L | PEFY-P25VMS1-E | PEFY-P32VMA3-E | PEFY-P32VMR-E-L | PEFY-P32VMS1-E | PEFY-P40VMA3-E | PEFY-P40VMHS-E | PEFY-P40VMS1-E | PEFY-P50VMA3-E | PEFY-P50VMHS2-E | PEFY-P50VMHS-E | PEFY-P50VMS1-E | PEFY-P63VMA3-E | PEFY-P63VMHS2-E | PEFY-P63VMHS-E | PEFY-P63VMS1-E | PEFY-P71VMA3-E | PEFY-P71VMHS2-E | PEFY-P71VMHS-E | PEFY-P80VMA3-E | PEFY-P80VMHS2-E | PEFY-P80VMHS-E | PFFY-P20VCM-E | PFFY-P20VKM-E | PFFY-P20VLEM-E | PFFY-P20VLRM-E | PFFY-P25VCM-E | PFFY-P25VKM-E | PFFY-P25VLEM-E | PFFY-P25VLRM-E | PFFY-P32VCM-E | PFFY-P32VKM-E | PFFY-P32VLEM-E | PFFY-P32VLRM-E | PFFY-P40VCM-E | PFFY-P40VKM-E | PFFY-P40VLEM-E | PFFY-P40VLRM-E | PFFY-P50VCM-E | PFFY-P50VLEM-E | PFFY-P50VLRM-E | PFFY-P63VCM-E | PFFY-P63VLEM-E | PFFY-P63VLRM-E | PKFY-P100VKM-E | PKFY-P10VLM-E | PKFY-P15VLM-E | PKFY-P20VLM-E | PKFY-P25VLM-E | PKFY-P32VLM-E | PKFY-P40VLM-E | PKFY-P50VLM-E | PKFY-P63VKM-E | PKFY-WL10VLM | PKFY-WL15VLM | PKFY-WL20VLM | PKFY-WL25VLM | PKFY-WL32VLM | PLFY-EP50VEM-E | PLFY-EP63VEM-E | PLFY-EP80VEM-E | PLFY-M100VEM-E | PLFY-M125VEM-E | PLFY-M20VEM-E | PLFY-M25VEM-E | PLFY-M32VEM-E | PLFY-M40VEM-E | PLFY-M50VEM-E | PLFY-M63VEM-E | PLFY-M80VEM-E | PLFY-P100VLMD-E | PLFY-P125VLMD-E | PLFY-P15VFM-E | PLFY-P20VFM-E | PLFY-P20VLMD-E | PLFY-P25VFM-E | PLFY-P25VLMD-E | PLFY-P32VFM-E | PLFY-P32VLMD-E | PLFY-P40VFM-E | PLFY-P40VLMD-E | PLFY-P50VFM-E | PLFY-P50VLMD-E | PLFY-P63VLMD-E | PLFY-P80VLMD-E | PMFY-P20VBM-E | PMFY-P25VBM-E | PMFY-P35VBM-E | PMFY-P40VBM-E | MFZ-KJ25VE | MFZ-KJ35VE | MFZ-KJ50VE | MFZ-KT25VG | MFZ-KT35VG | MFZ-KT50VG | MFZ-KT60VG | MLZ-KP25VF | MLZ-KP35VF | MLZ-KP50VF | MSY-TP35VF | MSZ-AP15VG | MSZ-AP20VG | MSZ-AP25VG | MSZ-AP25VGK | MSZ-AP35VGK | MSZ-AP42VG | MSZ-AP42VGK | MSZ-AP50VGK | MSZ-AP60VGK | MSZ-AP71VGK | MSZ-DM35VA | MSZ-EF18VGK W/B/S | MSZ-EF22VGK W/B/S | MSZ-EF25VGK W/B/S | MSZ-EF35VGK W/B/S | MSZ-EF42VGK W/B/S | MSZ-EF50VGK W/B/S | MSZ-FH25VE | MSZ-FH35VE | MSZ-FH50VE | MSZ-HR25VF | MSZ-HR35VF | MSZ-HR42VF | MSZ-HR50VF | MSZ-LN18VG W | MSZ-LN18VG2 V/B/R | MSZ-LN18VG2 W | MSZ-LN25VG2 V/B/R | MSZ-LN25VG2 W | MSZ-LN35VG2 V/B/R | MSZ-LN35VG2 W | MSZ-LN50VG2 V/B/R | MSZ-LN50VG2 W | MSZ-LN60VG2 V/B/R | MSZ-LN60VG2 W | MSZ-SF15VA | MSZ-SF20VA | MSZ-SF25VE | MSZ-SF35VE | MSZ-SF42VE | MSZ-SF50VE | MUSY-TP35VF | MUSY-TP50VF | MXZ-4E72VA-E2 | SEZ-M25DA | SEZ-M35DA | SEZ-M50DA | SEZ-M60DA | SEZ-M71DA | SLZ-M15FA | SLZ-M25FA | SLZ-M35FA | SLZ-M50FA | SLZ-M60FA | PCA-M100KA | PCA-M125KA | PCA-M140KA | PCA-M35KA | PCA-M50KA | PCA-M71KA | PCA-M80KA | PEAD-M125JA | PEAD-M140JA | PEAD-M35JA | PEAD-M50JA | PEAD-M71JA | PEAD-M80JA | PEA-RP200VVKA | PEA-RP250VVKA | PEA-RP250WKA | PKA-M100KAL | PKA-M35HAL | PKA-M50HAL | PKA-M71KAL | PKA-M80KAL | PLA-M100EA | PLA-M125EA | PLA-M140EA | PLA-M35EA | PLA-M50EA | PLA-M60EA | PLA-M71EA | PLA-ZM100EA | PLA-ZM125EA | PLA-ZM140EA | PLA-ZM35EA | PLA-ZM50EA | PLA-ZM60EA | PLA-ZM71EA | PSA-M100KA | PSA-M125KA | PSA-M140KA | PSA-RP100KA | PSA-RP125KA | PSA-RP140KA | PSA-RP71KA

* The asterisks stand for any character in the asterisk' position.

ORDER CODE:

INKNXMIT001I000  Mitsubishi Electric Domestic, Mr.Slim and City Multi to KNX Interface - 1 unit

INCLUDED COMPONENTS:

  • Intesis Gateway.
  • Installation Manual.
  • AC Connection cable.

Warranty: 36 months.

KNX Gateways for Air Conditioner

For the last decade, Intesis gateways have been the reference for Air Conditioning systems integration into KNX projects. Intesis offers specific solutions for the most popular AC brands and also a universal solution based on infrared communication.

With our infrared solution, the guest may enjoy a natural AC integration: users may keep their native AC remote controller thanks to a built-in IR receptor, which reports user AC commands to KNX.

KNX Gateways specific features

For one to one solutions


For multi-unit solutions


KNX AC Interfaces
one-to-one_inverted

One gateway, one AC unit.

This is the idea of one to one integration. As simple and fast as it seems.

  • All the required DPT objects to be compatible with all KNX thermostats in the market.
  • Grow in functionality with the binary inputs available in most of the gateways.
  • Advanced configuration available for the best AC experience: presence, window contact…
multi-unit_inverted

One Gateway, multiple AC units

The desired option for VRF integration: a unique device to fully integrate your AC system.

  • Smooth integration of KNX thermostats thanks to our “virtual temperature” function.
  • Wide range of standard DPTs ensuring interoperability with other KNX devices.
  • Device configuration templates. Configure once, use endless in your projects!

How to buy

At HMS networks, we are committed to building lasting relationships with our customers.

Find-distributor

Find a distributor

HMS delivers leading solutions to consumers all over the world every day. HMS distributors are carefully selected to offer the best localized sales, technical support and customer service in your country.

 

Find a distributor

customer-serice

Make an enquiry

Do you need further assistance? Please do not hesitate to contact our knowledgeable and friendly sales and customer service staff, who can help you with your Intesis enquiry.

Sales enquiries: +46 (0)35 17 29 58

 

Make an online enquiry

order-information

Purchasing information

Need to send an order to HMS? Are you a first-time buyer? Do you have questions about our terms and conditions, banking, delivery and shipment methods? Can you pay with a credit card? Here you can find all the information you need.

 

Purchasing information