Modbus AC brand Solution

Find your gateway solution to integrate AC units into Modbus systems. Our AC Interfaces makes easy the integration and ensures the compatibility as a major factor to enable maximum efficiency.
HMS_web-icon_Backup

Ensure energy savings

Intesis AC gateways allow to reduce considerably the energy consumption of buildings while contributing to environment protection.

HMS_web-icon_Solution Partner

Improve user's comfort

The goal is to reduce energy while improving user’s comfort. With Intesis these are not mutually exclusive outcomes!

fan-and-vane

Leading with leaders

We are the indisputable market leader in AC integration thanks to have the continuous support of the major AC manufacturers.

Panasonic ECOi, ECOg and PACi systems to Modbus TCP/RTU Interface

The Panasonic interface has been specially designed to allow bidirectional control and monitoring of Panasonic ECOi, ECOg and PACi systems from a BMS, SCADA, PLC or any other device working as a Modbus master.

FEATURES

  • Direct access to outdoor unit’s communication bus.
  • Scan: Automatic identification of the units presents in the VRF system.
  • Outdoor unit’s signals available for the integration.
  • The interface is a Modbus slave able to manage Modbus TCP and Modbus RTU simultaneously.
  • Up to 6 Modbus TCP clients (incoming sockets) are supported.
  • Datalogging through external USB port.
  • Configuration through IP or USB (Console) port.
  • Front cover LED indicators to provide easy to check communication status on both the Ethernet and serial ports.
  • Automatic updates for both Intesis MAPS and interface’s firmware.

 

panasonic-modbus-ac-interface-v6-gateway

Panasonic VRF systems to Modbus Gateway integration example (up to 128 Indoor Units).

PA-AC-MBS_128

Panasonic VRF systems to Modbus Gateway integration example (up to 64 Indoor Units).

PA-AC-MBS_16-64

DIRECT CONNECTION TO VRF OUTDOOR UNITS

The gateway is directly connected to the outdoor units communication bus and enables the control of all the indoor units connected to the system. This allows not only the control and monitoring of the main AC functions but the access to some internal variables of the outdoor units.

SET UP BY INTESIS MAPS    

The configuration is carried out using the Intesis MAPS software. This one allows you to define your own settings for the device and offers extra functions available for all the new generation gateways. Thanks to the scan function, which allows to automatically discover all the units available in the installation, get the interface ready to work in a really short time. 

Intesis MAPS makes it easy to identify any malfunction in the installations thanks to its robust diagnostic feature.

User Manual General information about this product Download
Installation Manual INMBSPANxxxO000 Learn how to install the device in your project Download
Installation Manual INMBSPAN128O000 Learn how to install the device in your project Download

Programming tools

Intesis MAPS Software tool

Mini-portfolio Discover all the integration solutions for Panasonic
Download
Intesis Brochure
Know more about the Intesis current available products
Download
INMBSPAN016O000  Panasonic ECOi, ECOg and PACi systems to Modbus TCP/RTU Interface - 16 units
INMBSPAN064O000  Panasonic ECOi, ECOg and PACi systems to Modbus TCP/RTU Interface - 64 units
INMBSPAN128O000  Panasonic ECOi, ECOg and PACi systems to Modbus TCP Interface - 128 units

INCLUDED COMPONENTS:

  • Intesis Gateway.
  • Installation Manual.
  • USB Configuration cable.
  • (Power supply not included).

Warranty: 2 years.

Modbus Slave Gateways for Air Conditioner

Intesis offers one of the largest portfolios of Modbus integration gateways for Air Conditioners on the market. The consistent Modbus register mapping used for all AC brands, helps improving the integration time of each project.

One Modbus map development, multiple usability in your projects. AC integration in Modbus was never that simple .

Modbus Gateways for Air Conditioner

For one to one solutions


For multi-unit solutions


Modbus AC Interfaces
one-to-one_inverted

One gateway, one AC unit.

This is the idea of one to one integration. As simple and fast as it seems.

  • Consistent register mapping presents common interface for all AC brands.
  • Fast an easy configuration thanks to the DIP-SW available on the product.
  • Wide register map covering not only a basic AC control but advance functionalities.
multi-unit_inverted

One gateway, multiple AC units.

The desired option for VRF integration: a unique device to fully integrate your AC system.

  • Supports both Modbus RTU and Modbus TCP simultaneously.
  • Control all the units connected from a single Modbus register.
  • Independent Modbus registers for individual control and monitoring.

How to buy

At HMS networks, we are committed to building lasting relationships with our customers.

Find-distributor

Find a distributor

HMS delivers leading solutions to consumers all over the world every day. HMS distributors are carefully selected to offer the best localized sales, technical support and customer service in your country.

 

Find a distributor

customer-serice

Make an enquiry

Do you need further assistance? Please do not hesitate to contact our knowledgeable and friendly sales and customer service staff, who can help you with your Intesis enquiry.

Sales enquiries: +46 (0)35 17 29 58

 

Make an online enquiry

order-information

Purchasing information

Need to send an order to HMS? Are you a first-time buyer? Do you have questions about our terms and conditions, banking, delivery and shipment methods? Can you pay with a credit card? Here you can find all the information you need.

 

Purchasing information